Thermostats, Controllers On/Off 1 Relay 32x74 |
|
| OT31-A Model | |
| Economical thermostat, 220 vac direct, switched contact, 32x74 case, IP65 | |
|
Input Type: PTC Ranges without DEC: -55 to 140 Ranges with DEC: -19,9 a 19.9 |
Tension: 220 Optional Tension: |
| OT31 Model | |
| Economical thermostat, 12 v direct, switched contact, 32x74 case, IP65 |
Input Type: PTC Ranges without DEC: -55 to 99 Ranges with DEC: |
Tension: 12 Optional tension: 24-48 |
| OT31-C Model | |
| Thermostat “blocked” parameters switched contact, 32x72 case, IP65 | |
|
Input Type: PTC Ranges without DEC: -55 to 140 Ranges with DEC: -19,9 a 19.9 |
Tension: 220 Optional tension: 12-24-48 |
| OT31-0 Model | |
| 3 digits thermostat, 12 v direct, switched contact, 32x74 case, IP65 | |
|
Input Type: PTC Ranges without DEC: -55 to 140 Ranges with DEC: -9.9 a 99.9 |
Tension: 12 Optional tension: 24-48 |
| OC31-PT Model | |
| 3 digits thermostat, 12 v direct, switched contact, 32x74 case, IP65 | |
|
Input Type: PT100 Ranges without DEC: -80 to 400 Ranges with DEC: -9.9 a 99.9 |
Tension: 12 Optional tension: 24-48 |
| OC31-J/K/S Model | |
| 3 digits thermostat, 12 v direct, switched contact, 32x74 case, IP65 | |
|
Input Type: J/K/S Ranges without DEC: 0 to 999 Ranges with DEC: |
Tension: 12 Optional tension: 24-48 |
| OC31-MA Model | |
| 3 digits controller, humidity/pressure, 1 relay switched contact, 32x74 case, IP65 | |
|
Input Type: 4..20 mA Ranges without DEC: -99 to 999 Ranges with DEC: -9.9 a 99.9 |
Tension: 12 Optional tension: 24-48 |
|
Thermostats, Controllers On/Off 2 Relays 32x74 |
|
| OC51-0 Model | |
| Thermostat 2 independent relays or relay+alarm or reg Zone M. IP65, 32x74 | |
|
Input Type: PTC Ranges without DEC: -55 to 140 Ranges with DEC: -9.9 a 99.9 |
Tension: 12 Optional tension: 24-48 |
| OC51-PT Model | |
| Thermostat 2 independent relays or relay+alarm or reg Zone M. IP65, 32x74 | |
|
Input Type: PT100 Ranges without DEC: -80 to 400 Ranges with DEC: -9.9 a 99.9 |
Tension: 12 Optional tension: 24-48 |
| OC51-J/K/S Model | |
| Thermostat 2 independent relays or relay+alarm or reg Zone M. IP65, 32x74 | |
|
Input Type: J/K/S Ranges without DEC: 0 to 999 Ranges with DEC: |
Tension: 12 Optional tension: 24-48 |
| OC51-MA Model | |
| 3 digits controller, humidity/pressure, 2 relay switched contact, IP65 32x74 case. | |
|
Input Type: 4..20 mA Ranges without DEC: -99 to 999 Ranges with DEC: -9.9 a 99.9 |
Tension: 12 Optional tension: 24-48 |
|
Thermostats, On/Off, PID 1 Relay 72x72 |
|
| OC32-0 Model |
|
| 72x72 thermostat, with programmable decimal point, back round casing, 1 relay. | |
|
Input Type: PTC Ranges without DEC: -55 to 140 Ranges with DEC: -9.9 a 99.9 |
Tension: 220 Optional tension: 12-24-48 |
| OC32-PT Model | |
| 72x72 thermostat, with programmable decimal point, back round casing, 1 relay. | |
|
Input Type: PT100 Ranges without DEC: -80 to 400 Ranges with DEC: -9.9 a 99.9 |
Tension: 220 Optional tension: 12-24-48 |
| OG32-0 Model | |
| 72x72 thermostat, 1 relay, with programmable decimal point, back scare casing. | |
|
Input Type: PTC Ranges without DEC: -55 to 140 Ranges with DEC: -9.9 a 99.9 |
Tension: 220 Optional tension: 12-24-48 |
| OG32-PT Model | |
| 72x72 thermostat, 1 relay, with programmable decimal point, back scare casing. | |
|
Input Type: PT100 Ranges without DEC: -80 to 400 Ranges with DEC: -9.9 a 99.9 |
Tension: 220 Optional tension: 12-24-48 |
| OC32-J/K/S Model | |
| 72x72 thermostat, 1 relay, programmable, back square casing. | |
|
Input Type: J/K/S Ranges without DEC: 0 to 1600 Ranges with DEC: |
Tension: 220 Optional tension: 12-24-48 |
| OG32-MA Model | |
| 72x72 controller, 1 relay, with programmable decimal point, back square casing. | |
|
Input Type: 4..20 mA Ranges without DEC: -99 to 999 Ranges with DEC: -9.9 a 99.9 |
Tension: 220 Optional tension: 12-24-48 |
|
Thermostats, Controllers On/Off, 2 PID Relays 72x72 |
|
| OG52-0 Model |
|
| 72x72 thermostat, 2 relays, with programmable decimal point, back square casing. | |
|
Input Type: PTC Ranges without DEC: -55 to 140 Ranges with DEC: -9.9 a 99.9 |
Tension: 220 Optional tension: 12-24-48 |
| OG52-PT Model | |
| 72x72 thermostat, 2 relays, with programmable decimal point, back square casing. | |
|
Input Type: PT100 Ranges without DEC: -80 to 400 Ranges with DEC: -9.9 a 99.9 |
Tension: 220 Optional tension: 12-24-48 |
| OC52-J/K/S Model | |
| 72x72 thermostat, 2 relays, programmable, back square casing. | |
|
Input Type: J/K/S Ranges without DEC: 0 to 1600 Ranges with DEC: |
Tension: 220 Optional tension: 12-24-48 |
| OG52-MA Model | |
| 72x72 controller, 2 relays, with programmable decimal point, back square casing. | |
|
Input Type: 4..20 mA Ranges without DEC: -99 to 999 Ranges with DEC: -9.9 a 99.9 |
Tension: 220 Optional tension: 12-24-48 |
|
Thermostats, Controllers On/Off, 1 PID Relay 96x96 |
|
| OG96-PT Model | |
| 96x96 thermostat, 1 relay, with programmable decimal point, back scare casing. | |
|
Input Type: PT100 Ranges without DEC: -80 to 400 Ranges with DEC: -9.9 a 99.9 |
Tension: 220 Optional tension: 12-24-48 |
| OG96-J/K/S Model | |
| 96x96 thermostat, 1 relay, programmable, back square casing. | |
|
Input Type: J/K/S Ranges without DEC: 0 to 1600 Ranges with DEC: |
Tension: 220 Optional tension: 12-24-48 |
| OG96-mA Model | |
| 96x96 controller, relay, with programmable decimal point, back square casing. | |
|
Input Type: 4..20 mA Ranges without DEC: -99 to 999 Ranges with DEC: -9.9 a 99.9 |
Tension: 220 Optional tension: 12-24-48 |
|
Thermostats, Controllers On/Off, 2 PID Relays 96x96 |
|
| OG96-PT-2 Model | |
| 96x96 thermostat, 2 relays, with programmable decimal point, back square casing. | |
|
Input Type: PT100 Ranges without DEC: -80 to 400 Ranges with DEC: -9.9 a 99.9 |
Tension: 220 Optional tension: 12-24-48 |
| OG96-J/K/S-2 Model | |
| 96x96 thermostat, 2 relays, programmable, back square casing. | |
|
Input Type: J/K/S Ranges without DEC: 0 to 1600 Ranges with DEC: |
Tension: 220 Optional tension: 12-24-48 |
| OG96-mA-2 Model | |
| 96x96 controller, 2 relays, with programmable decimal point, back square casing. | |
|
Input Type: 4..20 mA Ranges without DEC: -99 to 999 Ranges with DEC: -9.9 a 99.9 |
Tension: 220 Optional tension: 12-24-48 |
|
Thermostats, Controllers Case Din RAIL, 1 relay |
|
| OR31-0 Model |
|
| Din RAIL Thermostat, 1 relay, with programmable decimal point. | |
|
Input Type: PTC Ranges without DEC: -55 to 140 Ranges with DEC: -9.9 a 99.9 |
Tension: 220 Optional tension: 12-24-48 |
| OR31-PT Model | |
| Din RAIL Thermostat, 1 relay, with programmable decimal point. | |
|
Input Type: PT100 Ranges without DEC: -80 to 400 Ranges with DEC: -9.9 a 99.9 |
Tension: 220 Optional tension: 12-24-48 |
| OR31-J/K/S Model | |
| Din RAIL thermostat, 1 relay, programmable. | |
|
Input Type: J/K/S Ranges without DEC: 0 to 999 Ranges with DEC: |
Tension: 220 Optional tension: 12-24-48 |
| OR31-mA Model | |
| Din RAIL controller, 1 relay, with programmable decimal point. | |
|
Input Type: 4..20 mA Ranges without DEC: -99 to 999 Ranges with DEC: -9.9 a 99.9 |
Tension: 220 Optional tension: 12-24-48 |
|
Thermostats, Controllers Case Din RAIL, 2 relayés; |
|
| OR51-0 Model | |
| DinRAIL Thermostat, 2 relays, with programmable decimal point. | |
|
Input Type: PTC Ranges without DEC: -55 to 140 Ranges with DEC: -9.9 a 99.9 |
Tension: 220 Optional tension: 12-24-48 |
| OR51-PT Model | |
| DinRAIL Thermostat, 2 relays, with programmable decimal point. | |
|
Input Type: PT100 Ranges without DEC: -80 to 400 Ranges with DEC: -9.9 a 99.9 |
Tension: 220 Optional tension: 12-24-48 |
| OR51-J/K/S Model | |
| Thermostat DinRAIL, 2 relays, programmable. | |
|
Input Type: J/K/S Ranges without DEC: 0 to 999 Ranges with DEC: |
Tension: 220 Optional tension: 12-24-48 |
| OR51-mA Model | |
| DinRAIL Cotroller, 2 relays, with programmable decimal point. | |
|
Input Type: 4..20 mA Ranges without DEC: -99 to 999 Ranges with DEC: -9.9 a 99.9 |
Tension: 220 Optional tension: 12-24-48 |
| ORS-2/CONF Model | |
| Thermostat 2 independent relays/relay + alarm or reg. Zone, M. | |
|
Input Type: config Ranges without DEC: -99 to 999 Ranges with DEC: -9.9 a 99.9 |
Tension: 220 Optional tension: 12-24-48 |
|
Regulators ON/OFF, PID 48X96, DinRAIL, Comunication RS485 |
|
| OS98 Model-Temp, RR | |
| Thermostat 2 48x96 display vertical PID, autotuning 2 relays ind. prog., M zone or 1 relay + alarm. | |
|
Input Type: PT100, J/K/S Ranges without DEC: PT100(-200 / +600) J(-200 / +950) K(-200 / 1370) S(-50 / +1760) T(-270/400) R (-50/1760) Ranges with DEC: Check |
Tension: 220 Optional tension: 12-24-48 |
| OS98 Model-Temp, RRR | |
| Thermostat 3 48x96 display vertical PID, autotuning 2 relays ind. prog., M zone or 1 relay + alarm. | |
|
Input Type: PT100, J/K/S Ranges without DEC: PT100(-200 / +600) J(-200 / +950) K(-200 / 1370) S(-50 / +1760) T(-270/400) R (-50/1760) Ranges with DEC: Check |
Tension: 220 Optional tension: 12-24-48 |
| OS98 Model-Temp, RRR | |
| Thermostat 4 48x96 display vertical PID, autotuning 2 relays ind. prog., M zone or 1 relay + alarm. | |
|
Input Type: PT100, J/K/S Ranges without DEC: PT100(-200 / +600) J(-200 / +950) K(-200 / 1370) S(-50 / +1760) T(-270/400) R (-50/1760) Ranges with DEC: Check |
Tension: 220 Optional tension: 12-24-48 |
| OS98 Model-Temp, RRRR | |
| Thermostat 5 48x96 display vertical PID, autotuning 2 relays ind. prog., M zone or 1 relay + alarm. | |
|
Input Type: PT100, J/K/S Ranges without DEC: PT100(-200 / +600) J(-200 / +950) K(-200 / 1370) S(-50 / +1760) T(-270/400) R (-50/1760) Ranges with DEC: Check |
Tension: 220 Optional tension: 12-24-48 |
| OS98 Model-mA, RR | |
| Controller 2 display 48x48 PID, autotuning 2 relays ind. prog., zone M or 1 relay + alarm. | |
|
Input Type: mA Ranges without DEC: mA (-999 / 9999) Ranges with DEC: Check |
Tension: 220 Optional tension: 12-24-48 |
| IN-OUT 0/4..20 mA Model | |
| Optional regulation/s output proportional to process, several possibilities. | |
|
Input Type: Output Ranges without DEC: Ranges with DEC: |
Tension: Optional Tension: |
| IN-OUT 0-1/5/10 V Model | |
| Optional regulation/s output proportional to process, several possibilities. | |
|
Input Type: Output Ranges without DEC: Ranges with DEC: |
Tension: Optional Tension: |
| RS485 Output | |
| Optional communication output RS485/RS232 computer communication. | |
|
Input Type: Output Ranges without DEC: Ranges with DEC: |
Tension: Optional Tension: |
| ORS-2/RS485 Model | |
| Thermostat 2 independent relays/relay + alarm or reg. M zone, with RS485 communication. | |
|
Input Type: Config Ranges without DEC: Ranges with DEC: |
Tension: 220 Optional tension: 12-24-48 |
| ORS-2/CONF Model | |
| Thermostat 2 independent relays/relay + alarm or reg. Zone, M | |
|
Input Type: Config Ranges without DEC: Ranges with DEC: |
Tension: 220 Optional tension: 12-24-48 |
[ Return to Products Catalogue ] |
|